I threw together this robot in a couple of days to inspect my HVAC duct and pull a cable (side note: I’m aware it’s generally advised against to run a cable through a duct, but I live in LA and we don’t have heating in our HVAC system so I don’t see it as a problem)

It's a pretty bare-bones platform, designed to be as simple as possible for a quick design + build using parts I had on-hand.

The vehicle is powered by small geared 28BYJ-48 Stepper motors driven by ULN2003 drivers, controlled with an ESP32 Cam development board. It’s a decent board for the application as it has wifi, a camera and a bright forward facing LED. The board does not have the necessary 8 GPIO pins to drive the ULN chips, so I used a 8 bit shift register.

I originally intended it to be powered by an 18650 battery but I had problems using a boost converter to get the required current to drive the electronics at 5v. the board is pretty power hungry, and coupled with the steppers and high power LED, it wouldn't even boot. I resorted to using 2 lithium polymer batteries in series to achieve 7.2v with no boost converter, which worked well enough. Even then, use of the LED kept causing brown-outs and reboots so I resorted to lowering it to 1/4 duty cycle which fixed the problem.

I used Micropython and the Picoweb framework to serve a REST API for rover control and a web page to provide a UI:

The rover was designed in FreeCAD and printed on my Voron 0 using PLA. The tires were printed in NinjaFlex TPU which is a very flexible rubber like plastic, in order to provide more traction.

The rover suffered from the aforementioned brown-outs due to the LED power requirements and also struggled to turn in certain locations in the ducts due to traction limitations and as side effect of being 2WD, but ultimately succeeded at what I needed.

top 26 comments
sorted by: hot top controversial new old
[–] [email protected] 52 points 9 months ago

This needs a picture of Bruce Willis taped to the front…

[–] [email protected] 17 points 9 months ago

You'd better hope this little son of a bitch doesn't become self aware.

[–] [email protected] 15 points 9 months ago

This is the coolest shit I've seen all week. Great work, you have a lot of specific knowledge.

[–] [email protected] 13 points 9 months ago (2 children)

If it was pulling a cable anyways you could have had it tethered so you wouldn't have power issues and the danger of the WiFi dropping out from the metal duct. If it was pulling Ethernet the whole thing could have been POE but I guess if you were pulling off a spool you wouldn't be able to PoE the whole spool. Either way that's an interesting solution to not have to fight with fish tape.

[–] [email protected] 6 points 9 months ago

Yes - using POE for power and data crossed my mind! But ultimately I ended up only towing fishing line which I then used to pull the cable, which was probably easier than directly towing shielded cat 6!

[–] [email protected] 2 points 9 months ago

Well... Imagine s/he terminated the end of the spool, and basically had the other end hooked up to the bot? Depending on the distance, gently twisting the cable going from a PC to the spool could be fine, avoiding the need for slip-rings, etc.

[–] [email protected] 10 points 9 months ago (3 children)

Just FYI, it’s usually fine to run cable through ducting. It’s usually only against code to run it when you have the walls open. Meaning a remodeling crew wouldn’t be able to get away with it, but a homeowner is usually in the green.

[–] [email protected] 12 points 9 months ago

If you're going to run it through duct work, ensure the cable is plenum rated. For Ethernet cable, the jacket will be stamped "CMP".

[–] [email protected] 9 points 9 months ago

There are specific cable ratings for specific situations. CMR for risers or going between drops vertically. Rated for a slower burn. CMP for plenum as the other poster mentioned is for use in ducts. It’s rated to give off less toxic gases during a fire which is important since the ducts distribute air throughout your house.

[–] [email protected] 5 points 9 months ago

that's great information - thanks!

[–] [email protected] 5 points 9 months ago

That's a really cool project.

It's wild that you control it via web server.

[–] [email protected] 4 points 9 months ago

This is amazing.

[–] [email protected] 4 points 9 months ago (4 children)

What's its name? Maybe call it Gordon Freeman.

[–] [email protected] 13 points 9 months ago (1 children)

Really? Its air vents. We are in the Christmas season. And you do not suggest John McLane? How dare you, sir? How dare you?

[–] [email protected] 2 points 9 months ago (1 children)
[–] [email protected] 2 points 9 months ago (1 children)
[–] [email protected] 1 points 9 months ago
[–] [email protected] 9 points 9 months ago* (last edited 9 months ago)

Well, it's a gadget to inspect things... You could say it's an Inspector Gadget.

[–] [email protected] 5 points 9 months ago (1 children)

I unimaginatively called it Duct Rover 9000 but I like that, or Mclane :D

[–] [email protected] 3 points 9 months ago

Donald Duct

[–] [email protected] 1 points 9 months ago (1 children)

Is that a Kansas HVAC company ad reference!?

[–] [email protected] 2 points 9 months ago (1 children)

I like that you missed the half-life reference, and I missed the HVAC reference. Who is the Kansas guy???

[–] [email protected] 1 points 9 months ago

There's a large HVAC company in Kansas called that. I don't have any repartee.

[–] [email protected] 4 points 9 months ago

Amazing work! Such a cool and fun project.

[–] [email protected] 3 points 9 months ago

I love it, it does need some stickers, though. There are so many "it's/he's/she's in the air ducts!!!" scenes from various spy movies, though, it doesn't have to be a McLane reference. "Alias" had Sydney Bristow crawling through ducts, I can't remember specific episodes, though.

[–] [email protected] 3 points 9 months ago

That's a neat idea!