this post was submitted on 16 Nov 2023
12 points (100.0% liked)

Laser Cutting

427 readers
1 users here now

Share, discuss, troubleshoot, try not to blind yourself.

founded 1 year ago
MODERATORS
 

I've been trying to figure out the peak power demands and an uninterruptible power supply that can handle it. There doesn’t seem to be any documentation for this. It just needs to run long enough to power off safely. It's a Trotec speedy 360. Any help would be greatly appreciated!

Edit 360 not 400 and it's an 80W laser

Solved!

all 6 comments
sorted by: hot top controversial new old
[–] [email protected] 3 points 10 months ago* (last edited 10 months ago) (1 children)

You need a UPS that meets your wattage requirements for the amount of time you want to keep things on in the event of a loss of power.

Without the amount of time it's impossible to give any recommendations.

Here's a calculator to help you get your answer

Keep in mind that the wattage the laser is rated for might be lower than the total power draw of the system, so I'd get a watt meter and monitor your peak watts.

[–] [email protected] 2 points 10 months ago (3 children)

Thank you! I'm definitely a newbie, does a 120w CO2 laser only draw 120w?

[–] [email protected] 4 points 10 months ago* (last edited 10 months ago)

I would go off it the max wattage of the power supply the whole system uses instead of what the laser says.

That will have you covered for peak draw over the entire duration you're looking for, and will likely end up giving you a lot of wiggle room time wise.

I know almost nothing about laser engravers, but many of them are mechanically similar to 3D printers, which I do know a lot about, and stepper motors can suck down a lot of power.

[–] [email protected] 1 points 9 months ago* (last edited 9 months ago)

More directly answered, most CO2 lasers are rated in optical output power. There are a lot of inefficiencies before that, so e.g. the 85% efficient power supply, the (wild-ass-guess) 40% efficient laser, then you have other electrical loads like probably at least a dozen watts of fans, substantial power for motors, lights, controllers, air pumps if you have one...

I would expect a "120w" CO2 laser to have peak power consumption of at least 500w. You can use a kill-a-watt to check out the actual consumption while cutting, frankly I'd probably go with a 750-1200 kVA ups just for substantial fudge-factor.

Curious if you've already bought the UPS and if so how it's gone?