this post was submitted on 30 Apr 2024
180 points (98.4% liked)
Climate - truthful information about climate, related activism and politics.
5298 readers
719 users here now
Discussion of climate, how it is changing, activism around that, the politics, and the energy systems change we need in order to stabilize things.
As a starting point, the burning of fossil fuels, and to a lesser extent deforestation and release of methane are responsible for the warming in recent decades:
How much each change to the atmosphere has warmed the world:
Recommended actions to cut greenhouse gas emissions in the near future:
Anti-science, inactivism, and unsupported conspiracy theories are not ok here.
founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
Extreme energy use for pretty low deltas on temperature. Best possible efficiency is 100%, far less than the 2.5+ cop a heat pump unit will get you. If it's at all manageable, get the heat pump.
Frankly, their inefficiency means the emissions they cause are still pretty bad unless you know your energy source is more renewable than most.
But they don't need venting, which is nice. They do take a big fat electrical connection though - the one I installed was two 2 pole 40a breakers - hopefully you have at least 200A service. Mostly they work as intended.
Thanks. That makes sense. We installed a gas tankless after looking into electric tankless. The lack of venting looked really attractive until I blanched at the wiring we'd need to pull. My experience with tanked electrics was that they take a long time to recover. Is this also true of heat-pump based tanked WHs?