@SchmidtGenetics @rando my tap pressure had always been around 195. I now have 2 regulators inside house that I never needed before I got a new hot water heater. Incredible outside pressure, have to be careful with soaker in garden.
Pex is rated at 120 psi at hot water temperatures and only 160 psi at room temperature. So I seriously doubt that.
Rated pressure != burst pressure. I would expect a line rated at 160PSI line pressure to withstand at least 200PSI before bursting.
Water hammer can drastically increase line pressure; a line rated at 160PSI should be able to handle the transient pressure spikes that commonly occur in a 160PSI line.
Deliberately pushing 200PSI into a line rated for 160PSI is certainly not safe or acceptable, but I wouldn't be surprised to see it hold, and I would be surprised to see it fail.